Dura-Storm: Trusted as your first line of defense from hurricanes by withstanding high wind pressure and resisting forced entry.
Beauty and the Beast
    • Welded panels and reinforcements keep the panels on track, reduce door damange and increase protection from flying debris and looting.

    • Add style and sophistication with 2" narrow stiles and special finishes (patterned wood laminate shown).

    • Welded panels and reinforcements keep the panels on track, reduce door damange and increase protection from flying debris and looting.

    • Add style and sophistication with 2" narrow stiles and special finishes (patterned wood laminate shown).

Miami-Dade Compliant and Fast to Install
    • Compliant with Florida Building CodeMiami-Dade NOA Code, and ASTM E283. Tested to withstand winds up to 75psf and the impact of flyng debris.

    • Factory appllied environmentally-friendly 3M VHB eliminates time-consuming calking during install.

    • Compliant with Florida Building CodeMiami-Dade NOA Code, and ASTM E283. Tested to withstand winds up to 75psf and the impact of flyng debris.

    • Factory appllied environmentally-friendly 3M VHB eliminates time-consuming calking during install.

Watch the Dura-Storm Level E Video
    • Designed to increase the structural resilience of essential facilities, the Dura-Storm Level E provides the utmost protection against windborne debris and hurricane force wind loads when evacuation is not an option.

    • Designed to increase the structural resilience of essential facilities, the Dura-Storm Level E provides the utmost protection against windborne debris and hurricane force wind loads when evacuation is not an option.

STANDARD
Clear or Dark Bronze Anodized

OPTIONAL
Special Finishes
Alternate locking options
Medium 4" stiles
Narrow 2" stiles 
Transoms on non-impact rated

MODELS
Impact Rated Level E: Bi-Parting
  • Medium Stiles
  • Bi-part: 168” x 96”
  • Glass: 5/8”
Impact Rated: Bi-Parting and Single Slide 
  • Narrow / Medium Stiles: +/-  75 PSF
  • Bi-part: 168” x 96”
  • Single Slide: 108” x 96”
  • Glass: 9/16”
Impact Rated: Bi-Parting Only 
  • Medium Stiles - Steel Reinforced: +/- 55 PSF
  • Bi-part: 192” x 104” / 179.5” x 128”
  • Glass: 9/16
Non Impact Rated: Bi-Parting and Single Slide with Transom Option
  • Narrow / Medium Stiles: +/- 55 PSF
  • Bi-part: 168” x 96” (w/o transom) or 123.75” (w/ transom)
  • Single Slide with Optional Transom: 108” x 96” (w/o transom) or 123.75” (w/ transom)
  • Glass: ¼”, 1”
All door packages are custom manufactured to fit your job requirements up to ¼” increments.  For sizes greater or smaller than typical, contact your authorized STANLEY Access Technologies Sales Representative.

Detailed Information

 
DESIGN Single Slide or Bi-part
BREAKOUT SX Panel on the 2000, SX and SO panels on the 3000
FINISH Clear or Dark Bronze Anodized | OPTION: Special Finishes Available
TYPICAL HEIGHT 7’-8” (2.3m)
CLEAR DOOR OPENING Bipart 70.6” | Single Slide: 46.4”
HEADER SIZE 8” (203mm) High x 6” (152mm) Deep
JAMB DIMENSION 1 3/4” x 4 1/2” Option: 1 3/4” x 6”
STILES Narrow 2.0” or Medium 4.0"
BOTTOM RAIL 4" | OPTION: 6", 8", 10", 12"
TYPICAL DOOR PANEL WEIGHT Up to 220 Pounds Each (100kg)
MAXIMUM PANEL WEIGHT Up to 400lb (With Heavy Duty Option)
DOOR PANEL MATERIAL Aluminum
POWER REQUIRED 120 VAC, 50/60 HZ, 5 Amps Minimum | OPTION: Uninterrupted Power Supply
DRIVE SYSTEM 1/4 HP DC Motor, Gear Drive, Toothed belt | OPTION: Twin 1/4 HP DC Gear Driven Motors
CONTROLS Rocker Switch | OPTION: Rotary, Keyed Rotary Controls, Eco Pro
CONTROLLER Microprocessor Based, Safety Logic
ACTIVATION SENSORS 2 for Motion (Switchable Between Uni-directional and Bi-directional) | OPTIONAL: Mats, Wallplates, Radio Control
SAFETY SENSORS 1 Stan-Guard® and Doorway Holding Beam
LOCKING 5-point, Electric Solenoid Lock (Fail Safe/Fail Secure), Surface or Recessed Panic Hardware, Lock GuardArmored Strike
SECURITY OPTIONS Alarm Contacts for remote monitoring of panel status, Security Strobes for theft deterrence
CAMERA OPTIONS Jamb CameraStan Camera
TEMPERATURE RATING -30F to 130F
GLASS STOPS 1/4", 1" | 9/16" Impact Glass
MUNTINS One 2" | OPTION: 4 1/4"
THRESHOLD Configurable Options
TRANSOM Optional on Non Impact package only
CODES AND STANDARDS ANSI A156.10NFPA 101ULcULICBOBOCAFlorida Building CodeMiami-Dade County NOA Code Compliance, ASTM E283, Level E
  * All Specifications are subject to change. Please contact your local sales representative to ensure accuracy.
NO Illustration Description TYPE Model PDF DWG BIM/REVIT
2.01 Dura-Storm Impact Bi-Part 2000
2.02 Dura-Storm Impact Single Slide 2000
2.03 Dura-Storm Impact Bi-Part 3000
2.04 Dura-Storm Impact Single Slide 3000
2.05 Dura-Storm Non-Impact Bi-Part 2000
2.06 Dura-Storm Non-Impact Single Slide 2000
2.07 Dura-Storm Non-Impact Bi-Part 3000
2.08 Dura-Storm Non-Impact Single Slide 3000
2.09 Dura-Storm Impact Steel Reinforced Bi-Part 2000
2.10 Dura-Storm Impact Steel Reinforced Bi-Part 3000
2.11 Dura-Storm Impact Level E 3000
2.50 Dura-Storm Threshold Options 2000/3000
2.60 Dura-Storm Access Control Options 2000/3000
2.70 Dura-Storm Transom Options 2000/3000