Trackless Sliding Intensive Care Unit Doors
with breakaway capabilities for patient transport
Compare Door Opening
FIND THE RIGHT DOOR BASED ON YOUR NEEDS AND LIMITATIONS

Guidelines: 

  • Choose doors with the largest clear door opening for easier patient transport without having to breakaway the door.
  • Two panel doors are more cost effective, while 3-panel and 4-panel doors have smaller swing out into the patient room or corridor. 
  • Door frames should be 1/2" smaller than your rough opening. 

 

 

Clear Door Opening* for 7'-0 1/2" Rough Opening 

Clear Door Opening* for 8'-0 1/2" Rough Opening

Clear Door Opening* for 9'-0 ½” Rough Opening

2- and 4-PANEL

 

 

 

ProCare 8300

38.2"

44.2"

50.2"

Dura-Care 7300 TL-FBO

38.2"

44.2"

50.2"

ProCare 8300A Automatic

37.4"

43.4"

49.4"

Dura-Care 7200

35.3"

41.3"

47.3"

ProCare 8300BP

35.1”

41.1”

47.1”

Dura-Care 7000TL

33.3"

39.3"

45.3"

3-PANEL

 

 

 

Dura-Care 7500 TL

44.6"

52.6"

60.6"

Dura-Care 7500 TL-FBO

39.5"

47.5"

55.5"

Largest Door Opening
THE LARGEST CLEAR DOOR OPENING IN THE INDUSTRY FOR FAST AND EASY TRANSPORTS

MODELS

ProCare8300: 2-panel manual sliding door. Newly designed to protect patients with safer transfers and promote healing by eliminating disruptions. Clear door opening* is 44.2” on an 8’ door and 50.2 on a 9’ door.

Dura-Care 7500 Series: 3-panel manual sliding doors. Clear door opening* is 47.5” on an 8’ door and 55.5” on a 9’ door.

*Without positive latch

SOLUTIONS FOR

  • Patient Privacy
  • Frequent Breakaway for Patient Transports

APPLICATIONS

  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Smoke Rated Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same Day Surgery Rooms
  • Trauma Rooms
  • Large Office/Meeting Rooms
  • Bariatric Treatment Rooms
Smallest Breakaway Arc
SMALL BREAKAWAY ARC SO YOU NEVER HAVE TO COMPROMISE ON PATIENT ROOM DESIGN

MODELS

ProCare 8300BP: This compact 4-panel bi-part manual sliding door is STANLEY’s newest alternative to the standard sliding ICU door. Designed to protect patients with safer transfers and promote healing by eliminating disruptions. Breakaway arc is 23.7” on a 8’ and 26.7”on an 9’ door.  

Dura-Care 7500 TL-FBO: 3-panel sliding doors. Breakaway arc is 32.8”on an 8’ door.  And 36.8” on a 9’ door.

SOLUTIONS FOR

  • Space Optimization
  • Corridor Breakaway, Compliant with NFPA 101 Section 7.2.1.4.3.
  • Patient Privacy
  • Frequent Breakaway for Patient Transports

APPLICATIONS

  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Smoke Rated Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same Day Surgery Rooms
  • Trauma Rooms
  • Hospital Pharmacies
  • Operating Rooms
Automatic
TOUCHLESS AUTOMATION FOR INFECTION CONTROL

MODELS

ProCare8300A: 2-panel automatic sliding door. Jamb mounted touch-less wave activation and overhead safety sensors. Newly designed to protect patients with safer transfers and promote healing by eliminating disruptions. 

Dura-Care 7500A: 3-panel automatic sliding door. Jamb mounted touch-less wave activation and overhead safety sensors. 

SOLUTIONS FOR

  • Patient Privacy
  • Frequent Breakaway for Patient Transports
  • Infection Control

APPLICATIONS

  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Smoke Rated Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same Day Surgery Rooms
  • Trauma Rooms
  • Hospital Pharmacies
  • Operating Rooms
Surface/P-Panel
P-PANEL/SURFACE APPLIED MANUAL SLIDING DOORS

Surface applied manual door with single sliding panel and break out capabilities. 

SOLUTIONS FOR

  • Rough Opening Width Range: 35.3” x 106.3”
  • Clear Door Opening Width Range: 35.3” - 91.5”
  • Retrofit

APPLICATIONS

  • Renovations
  • Patient Bathrooms
  • ICU/CCUs
  • Pressurized Isolation Rooms
  • Emergency Department Treatment Rooms
  • Pre/Post Surgery Rooms
  • Same Day Surgery Rooms
  • Trauma Rooms
  • Office/Meeting Rooms