The average commercial building wastes 30% of the energy it consumes*.
Meet ASTM E283, improve thermal performance and decrease air infiltration by 61%*.
The average commercial building wastes 30% of the energy it consumes*.
Meet ASTM E283, improve thermal performance and decrease air infiltration by 61%*.
Lower HV/AC costs when there is low traffic or inclement weather by reducing the opening width.
Lower HV/AC costs by shaveing off an average of 1 second of open time when Fast Tracking is enabled.
Lower HV/AC costs when there is low traffic or inclement weather by reducing the opening width.
Lower HV/AC costs by shaveing off an average of 1 second of open time when Fast Tracking is enabled.

MODELS
Full Breakout (3000 only) All panels break out at any point of travel for large emergency egress. Video.
Partial Breakout (2000 only) Only sliding panel(s) break out at any point of travel. Surface mount options available. Video.
LEARN MORE ABOUT
U-Factor and automatic doors and find the right configuraiton based on your requirements.
Solar Heat Gain Coefficient and Visual Light Transmission ratings based on door configuration and glass type.
Learn about our sustainability practices throughout the life cycle of the product to help reach your building certification needs.
All door packages are custom manufactured to fit your job requirements up to ¼” increments. For sizes greater or smaller than typical, contact your authorized STANLEY Access Technologies Sales Representative.
* US EPA | **Compare to a standard 14' Dura-Glide bi-part.

Environmental Product Declaration available for download in the 'Reference Download' tab below
Detailed Information
DESIGN | Single Slide or Bi-part |
---|---|
BREAKOUT | SX Panel on the 2000, SX and SO panels on the 3000 | OPTION: Flush/ or surface mounted panic hardware. |
FINISH | Clear | OPTION: Special Finishes Available |
TYPICAL HEIGHT | 7’-8” (2.3m), Clear Door Opening of 6’-11” (2.1m) | OPTION: Taller options available, contact your local rep |
TYPICAL WIDTH SINGLE SLIDE (narrow stiles) | 7’ to 9’ (2.1 to 2.7m), CDO width 35 1/4” - 47 1/4” (896mm - 1201mm) 2000 Emergency Breakout: 39” - 51” (991mm - 1296mm) 3000 Emergency Breakout: 75” - 99” (1905mm - 2515mm) |
TYPICAL WIDTH BI-PART (narrow stiles): | 10’ to 14’ (3.0m - 4.3m), CDO width: 48 1/4” - 72 1/4” (1227mm - 1836mm) 2000 Emergency Breakout: 55 1/2” - 79 1/2” (1411mm - 2021mm) 3000 Emergency Breakout: 105 1/2” - 153 1/2” (2680mm - 3899mm) |
HEADER SIZE | 8” (203mm) High x 6” (152mm) Deep |
JAMB DIMENSION | 1 3/4” x 4 1/2” Option: 1 3/4” x 6” |
STILES | Narrow 2” | OPTION: Medium 3 1/2" |
BOTTOM RAIL | 4” | OPTION: 6”, 8”, 10”, 12” |
TYPICAL DOOR PANEL WEIGHT | Up to 220 Pounds Each (100kg) | OPTION: Heavier options available |
DOOR PANEL MATERIALS | Aluminum |
POWER REQUIRED | 120 VAC, 50/60 HZ, 5 Amps Minimum | OPTION: Uninterrupted Power Supply |
DRIVE SYSTEM | 1/4 HP DC Motor, Gear Drive, Toothed belt | OPTION: Twin 1/4 HP DC Motors |
CONTROLS | Rocker Switch (with Reduced Open) | OPTION: Rotary, Keyed Rotary Controls, Eco Pro, (all include Reduced Open) |
CONTROLLER | Microprocessor Based, Safety Logic |
ACTIVATION/SAFETYSENSORS | 2 Combined Activation/Safety Sensors + Holding Doorway Holding Beams for added safety | OPTION: Mats, Wall Plates, Wireless Activation systems |
LOCKING | Key/thumb turn hook bolt | OPTION: 3-Point Locking, Lock Position Indicators, Electric Solenoid Lock (Fail Safe/Fail Secure), Access Control Locking with Surface or Recessed Panic Hardware, Lock Guard, Armored Strike |
SECURITY OPTIONS | Alarm contacts for remote monitoring of panel status, Security Strobes, Delayed Egress |
CAMERA OPTIONS | Jamb Camera, Stan-Cam |
TEMPERATURE RATING | -30F to 130F |
GLASS STOPS | 1” | OPTION: 1/4" , 1/2", 5/8" |
GREENFIT SEALING SYSTEM | Default on for Air Infiltration: Dual Extended Concealed Sweeps, Additional Sweep Gap Fillers and Air Infiltration Blocks |
MUNTIN | One 2" muntin | OPTION: None, 4 1/4", Multiple |
THRESHOLD | Configurable Options (Continuous for GreenFit Sealing System) |
TRANSOM | Configurable Verticals and/or Horizontals |
SPEED RANGE | Closing Speeds: 0.5’ - 1.5 per sec per ANSI. Opening Speeds: 0.5’ - 2.5’ per sec. |
CODES AND STANDARDS | UL, cUL, ANSI/BHMA A156.10, ASTM E283 (NFRC 400), IBC, UBC, BOCA, ICBO, NFPA 101 |
Specifications subject to change. Contact your local STANLEY Rep to ensure accuracy. |
NO | Illustration | Description | TYPE | Model | DWG | BIM/REVIT | |
---|---|---|---|---|---|---|---|
1.22 |
![]() |
Dura-Glide GreenStar | Bi-Part | 2000 | |||
1.23 |
![]() |
Dura-Glide GreenStar | Single Slide | 2000 | |||
1.24 |
![]() |
Dura-Glide GreenStar | Bi-Part | 3000 | |||
1.25 |
![]() |
Dura-Glide GreenStar | Single Slide | 3000 | |||
1.80.01 | Dura-Glide GreenStar | Green-Set-Go | 2000 | ||||
1.80.02 | Dura-Glide GreenStar Optional Closer and Magnetic Latch | Green-Set-Go | 3000 |